NEW YORK STATE
MULTIPLE DWELLING LAW

Chapter 713 of the Laws of 1929, as amended


                            ARTICLE 5
                NON-FIREPROOF MULTIPLE DWELLINGS

Section             140. Application of article five.

                             TITLE 1
                         FIRE PROTECTION

Section             141. Height
                    142. Sub-curb uses.
                    143. Construction of first floor.
                    144. Egress from dwellings.
                    145. Fire-escapes.
                    146. Egress from apartments.
                    147. Bulkheads and scuttles.
                    148. Public stairs.
                    149. Public halls.
                    150. Cellar and basement stairs.
                    151. Spaces under stairs.
                    152. Fire-stopping.

                             TITLE 2
                           SANITATION

                    160. Water-closets.

=================================================================


Sec. 140. Application of article five.

The provisions of this article shall apply to non-fireproof
multiple dwellings erected after April eighteenth, nineteen
hundred twenty-nine, and to such dwellings only. They shall apply
to all such non-fireproof dwellings unless their application is
expressly limited to dwellings of a particular class. They shall
apply in addition to, and not in substitution for, the provisions
of article three. However the provisions of this article shall
not apply to a multiple dwelling three stories or less in height
to be occupied by not more than three families in all, with a
maximum occupancy of two families on each floor in a two story
building and one family on each floor in a three story building,
provided however that all the provisions of article six are
complied with, including section one hundred seventy-a of said
article.


                             TITLE 1
                         FIRE PROTECTION

Sec. 141. Height.

Any such dwelling which is seventy-five feet or less in height
above the curb level and has six stories or less may be of non-
fireproof construction.


Sec. 142. Sub-curb uses.

1.   When such a dwelling is more than eighty feet in height
     measured from the lowest point of the yard or of any curb on
     which any part of the dwelling faces, whichever is lower,
     and any room in such dwelling below the level of the highest
     curb which any part of such dwelling faces is occupied for
     living purposes as permitted in paragraph f of subdivision
     one of section thirty-four, the yard at the level of such
     highest curb shall be set back so as to be at least eight
     feet greater in depth than the yard below such level unless
     the yard opens directly upon a street.

2.   If such a dwelling is erected upon an interior lot running
     through from street to street, the wall of the dwelling
     facing the lowest street shall, at the level of the highest
     curb on which any part of such dwelling faces, be set back
     at least eight feet.

3.   The setback of the yard or wall required by each of the two
     preceding subdivisions shall be a fire-terrace. Nothing
     herein contained shall be construed to permit a yard of
     smaller dimensions below the level of such fire-terrace than
     required by paragraph f of subdivision one of section thirty-
     four.

4.   From each apartment below the level of such highest curb at
     least one means of egress shall lead directly to such fire-
     terrace in a manner approved by the department. Such fire-
     terrace shall be protected by a guard railing approved by
     the department, and shall afford safe and unobstructed
     access either directly to a street or to a covered fireproof
     passage at least three feet in width and seven feet in
     height leading directly and without obstruction to a street.

5.   In all portions of such dwellings below the level of the
     highest curb all structural members, partitions, furrings
     and ceilings shall be constructed of incombustible
     materials.

6.   Apartments may also be occupied for living purposes in
     cellars and basements in accordance with the provisions of
     subdivision six of section thirty-four.


Sec. 143. Construction of first floor.

1.   The first floor above the lowest cellar, or, if there be no
     cellar, above the lowest story, shall be fireproof or, if
     the dwelling be three stories or less in height, fire-
     retarded. Said first floor shall be unpierced except for a
     stair leading to a cellar as provided in section one hundred
     fifty, for lawful pipes, conduits and ducts and for
     dumbwaiter and elevator shafts. Any such dumbwaiter and
     elevator shafts shall be equipped at all openings below the
     said first floor with fireproof doors and assemblies with
     the doors self-closing.

2.   Whenever the lowest cellar does not extend over more than
     half the area of the dwelling, that portion of the first
     floor directly over such cellar and the entire second floor
     above such cellar shall be constructed as in this section
     prescribed for the first floor above the lowest cellar.
     Whenever the lowest cellar extends over more than half, but
     not all, of the area of the dwelling, only that portion of
     the first floor directly over such cellar need be
     constructed as in this section prescribed for the first
     floor above the lowest cellar.


Sec. 144. Egress from dwellings.

1.   A dwelling three or more stories in height shall have at
     least two means of egress extending to the roof from an
     entrance story, street, court or yard. The entrances to such
     means of egress at every story shall be at least fifteen
     feet distant from each other unless they are on opposite
     sides of a public hall. One means of egress shall be a stair
     constructed as provided in section one hundred forty-eight.
     The other means of egress shall be either another such stair
     or a fire-escape constructed as provided in section fifty-
     three.

2.   If the number of living rooms on any story, or in any
     section of any story, above the entrance story exceeds
     twenty, there shall be an additional stair, or fire-stair,
     extending from the entrance story to the roof for each
     twenty rooms or fraction thereof on such story or section
     thereof in excess of twenty, except that no additional
     stair, or fire-stair, shall be required for such excess on
     any story or section thereof if the number of living rooms
     thereon does not exceed thirty and if in addition one stair
     serving such story or section and every entrance hall or
     other public hall connected therewith are everywhere four
     feet six inches or more in clear width.

3.   There shall be accessible from every apartment two means of
     egress from the dwelling, one of which shall be a stair
     within fifty feet from a means of egress from such
     apartment. For such dwellings erected under plans filed in
     the department after September first, nineteen hundred fifty-
     one, such stair shall also be enclosed and comply with the
     provisions of section one hundred forty-eight.

4.   Whenever more than two stairs are required, one or more of
     such stairs may be fire-stairs or fire-towers, provided that
     there shall never be more than one such fire-stair or fire-
     tower for each two other required stairs.


Sec. 145. Fire-escapes.

Every fire-escape shall be located, arranged, constructed and
maintained as provided in section fifty-three.


Sec. 146. Egress from apartments.

1.   There shall be at least two means of egress from every
     apartment or suite. Such means shall be remote from each
     other. Except where it opens into a stair as permitted in
     subdivision three, one means shall be to a public hall
     connecting with a stair, fire-stair or fire-tower, not more
     than fifty feet distant from such means. In dwellings
     erected under plans filed in the department after September
     first, nineteen hundred fifty-one, such stair, fire-stair or
     fire-tower shall be enclosed. The other required means of
     egress shall open either directly upon a fire-escape or
     directly on a fire-tower balcony or a public vestibule or
     other public hall connecting with a stair, fire-stair or
     fire-tower balcony.

2.   Except as hereinafter provided for dwellings two stories or
     less in height such balcony, vestibule, hall or stair shall
     be separated from the public hall or stair on which the
     first means of egress opens by a fireproof wall, unpierced
     unless by an opening equipped with a fireproof door and
     assembly with the door self-closing. Such door shall not be
     held open by any device whatever. In a dwelling two stories
     or less in height, the separating wall may be fire-retarded
     on both sides in lieu of being fireproof.

3.   In a dwelling three stories or less in height and occupied
     by four families or less on each story, and in any section
     of a class A dwelling which is two stories or less in height
     and occupied by four families or less on each story, a means
     of egress from an apartment may open directly into a stair
     without the intervention of a public hall.


Sec. 147. Bulkheads and scuttles.

1.   Except as otherwise provided in subdivision two of this
     section, every required stair, fire-stair and fire-tower in
     dwellings three stories or more in height shall have a
     bulkhead constructed as provided for fireproof dwellings in
     section one hundred four, except that the bulkhead of any
     required stair which is not required to be fireproof may be
     built of wood covered on the outside with twenty-six gauge
     metal and on the inside with wire or metal lath covered with
     two coats of cement plaster or other fire-retarding material
     approved by the department.

2.   Such a dwelling which is two stories or less in height, or
     is three stories in height and erected pursuant to plans
     filed with the department on or after May first, nineteen
     hundred fifty-nine and occupied by not more than one family
     on each story, shall be provided at each required stair,
     fire-stair or fire-tower either with such a bulkhead or with
     a scuttle at least two feet by three feet in size, located
     in the ceiling of the public hall on the top story and so
     arranged as to provide direct and uninterrupted access to
     the roof. Every such scuttle shall be arranged to be readily
     opened, shall be covered on the outside with metal and shall
     be provided with stairs or a stationary iron ladder or
     ladders leading thereto and easily accessible to all the
     tenants of the dwelling.

3.   No bulkhead or other superstructure on the roof shall be
     used for human occupancy.

4.   When a dwelling has a pitched or sloping roof with a pitch
     or slope of more than fifteen degrees, no bulkhead or
     scuttle or stair or ladder leading thereto shall be
     required.


Sec. 148. Public stairs.

1.   Every stair, fire-stair and fire-tower shall, except as
     otherwise provided in subdivisions three and four of this
     section and section one hundred forty-nine, be constructed
     as provided for fire-stairs in sections one hundred two and
     one hundred five for fireproof dwellings.

2.   Every stair, fire-stair and fire-tower shall be at least
     three feet in clear width throughout, and at all floor
     levels shall have landings at least three feet six inches in
     clear width.

3.   Every stair, fire-stair and fire-tower shall be completely
     separated from every other stair, fire-stair and fire-tower
     and from every public hall and shaft by fireproof walls,
     with fireproof doors and assemblies, with the doors self-
     closing and without transoms, at all openings, except that
     in dwellings two stories or less in height such walls may be
     fire-retarded on both sides in lieu of being fireproof. The
     doors giving access to such stairs shall not be held open by
     any device whatever.

4.   Except in the case of an interior enclosed stair separated
     from and directly accessible to the public hall by a self-
     closing fireproof door and except as provided in subdivision
     five, there shall be provided to light and ventilate every
     stair at every story a window or windows opening on a
     street, court, yard or space above a setback. At least one
     such window shall be at least two feet six inches wide and
     five feet high unless it opens on a street, in which case
     its minimum height shall be four feet. The aggregate area of
     such window or windows at each story shall be at least
     eighteen square feet. On the top story a ventilating
     skylight may be substituted for a window. At the entrance
     story or at the roof level a sash door, such as described in
     section thirty-five, opening to the outer air may be
     substituted for such window.

5.   In a dwelling occupied by two families or less on every
     story:

     a.   If such dwelling is three stories or less in height,
          there may be provided for any stair, in lieu of
          windows, a stairwell sixteen inches or more in clear
          width extending from the entrance story to the roof.

     b.   If such dwelling is a class A dwelling and is two
          stories or less in height, there may be provided for
          any stair, in lieu of windows, a stairwell six inches
          or more in clear width. For the purposes of this
          paragraph a section of a class A multiple dwelling may
          be deemed a separate multiple dwelling.

     c.   If such dwelling is two stories in height and has no
          public hall on the first story, no stairwell or stair
          windows need be provided.


Sec. 149. Public halls.

1.   Every public hall shall be everywhere at least three feet in
     clear width.

2.   Every public hall shall be completely enclosed with
     fireproof floor, ceiling and walls, and, in dwellings
     erected under plans filed in the department after September
     first, nineteen hundred fifty-one, such hall shall be
     separated from every stair by fireproof partitions or walls.
     All doors and their assemblies opening from such hall or
     stairs shall be fireproof, with the doors self-closing and
     without transoms, except that in a dwelling three stories or
     less in height occupied by not more than four families on
     each story, or in a class A dwelling or any section thereof
     two stories or less in height, any such hall which furnishes
     access to only one stair need not be separated from such
     stair by any partition or door and the walls of a public
     hall may be fire-retarded and the floors may be provided
     with three inches or more of incombustible deafening
     materials between the beams instead of being fireproof.

3.   Except in dwellings three stories or less in height and
     occupied by two families or less on every story, and except
     as provided in subdivisions four to seven inclusive, every
     public hall shall have at least one window opening directly
     upon a street or upon a lawful yard or court. There shall be
     such a window at the end of each such hall and at right
     angles to its length, with an additional window in each
     forty feet of hall or fraction thereof beyond the first
     sixty feet from such end window; or the hall shall have one
     window opening directly upon a street or upon a lawful yard
     or court in every forty feet of its length or fraction
     thereof measured from one end of the hall.

4.   When the length of any recess or return off a public hall
     does not exceed twice the width of such recess or return, no
     window shall be required therein. But whenever the length of
     a recess or return exceeds twice its width, there shall be
     an additional window or windows meeting the requirements for
     a separate public hall. No entrance hall shall have a return
     or recess which exceeds in length twice its width.

5.   The foregoing provisions of this section with regard to
     lighting and ventilation shall not apply to a vestibule or
     other public hall which serves as a means of access from one
     or more apartments opening thereon to a fire-stair or fire-
     tower meeting the requirements of section one hundred forty-
     four if such vestibule or public hall is lighted and
     ventilated as required for fireproof dwellings by sections
     thirty-seven and one hundred seven.

6.   The foregoing provisions of this section with regard to
     lighting and ventilation shall not apply to that portion of
     an entrance hall between the first flight of stairs and the
     entrance provided the entrance door contains five square
     feet or more of glazed surface or such entrance hall does
     not extend from the outer entrance of the dwelling more than
     sixty feet.

7.   A passenger elevator vestibule not exceeding in length twice
     the parallel length of the elevator shaft or shafts opening
     into it need not be equipped with a window if it conforms to
     the requirements of sections thirty-seven and one hundred
     seven for public halls in fireproof multiple dwellings.
     Every door and its assembly separating such a vestibule from
     any public hall connected with a stair, fire-stair or fire-
     tower shall be fireproof, with the door self-closing and
     glazed with good quality wire glass ten square feet or more
     in area. No such door shall be kept open by any device
     whatever.

8.   Any part of a public hall that is shut off from any other
     part of such hall by a door or doors shall be deemed a
     separate hall.


Sec. 150. Cellar and basement stairs.

1.   Except as otherwise provided in this section, there shall be
     no inside stair communicating between the lowest cellar or
     the lowest story, if there be no cellar, and the floor next
     above, but any stair communicating between such floors shall
     be located outside the dwelling and if enclosed shall be
     fireproof in a fireproof enclosure with fireproof doors and
     door assemblies, with the doors self-closing, at all
     openings.

2.   This provision, however, shall not apply to any stair not
     extending through more than one story and leading from an
     entrance hall to the upper stories where the walls enclosing
     such hall are fireproof and unpierced except for openings to
     stairs, elevators, apartments, public reception rooms,
     professional offices and the outer air. In no event shall
     there be any other opening from such an entrance hall, and
     all apartments and such professional offices opening
     therefrom shall be entirely separated from any space within
     such dwelling used for any other purposes by fireproof walls
     which shall be unpierced except for means of egress into the
     entrance hall. The provisions of this subdivision shall not
     apply to openings which are protected with fireproof
     vestibules. Any such vestibule shall have a minimum
     superficial floor area of fifty square feet and its maximum
     area shall not exceed seventy-five square feet. It shall be
     enclosed with incombustible partitions having a fire-
     resistive rating of three hours. The floor and ceiling of
     such vestibule shall also be of incombustible material
     having a fire-resistive rating of at least three hours.
     There shall be two doors to provide access from the entrance
     hall and any other space not used for openings to stairs,
     elevators, apartments, public reception rooms and the outer
     air. Each such door shall have a fire-resistive rating of
     one and one-half hours and shall be provided with a device
     to prevent the opening of one door until the other door is
     entirely closed. One of these doors shall swing into the
     vestibule from the entrance hall and the other shall swing
     from the vestibule into space which it serves. Such
     vestibule shall also be equipped with sprinklers and with an
     independent exhaust duct having a minimum cross-sectional
     area of one hundred forty-four square inches for each one
     thousand cubic feet, or fraction thereof, of air content,
     and such exhaust duct shall not be connected with any other
     ventilating system.

3.   In dwellings three stories or less in height which are
     occupied by two families or less on every story, any stair
     leading to the cellar may be located inside the dwelling
     provided it is entirely enclosed with fireproof walls and
     with fireproof doors and door assemblies at both the cellar
     level and the story above, with the doors self-closing.

4.   The provisions of subdivision one shall not prohibit or
     apply to an inside stair extending from a space used for
     commercial purposes in the cellar or lowest story to a store
     on the story next above, provided such stair is of
     incombustible materials, has closed risers, is enclosed
     between the two lowest floors with walls having a three-hour
     fire resistive rating and has fireproof doors and door
     assemblies at top and bottom, with the doors self-closing,
     and provided such commercial space in the cellar or lowest
     story is completely enclosed with partitions having a fire-
     resistive rating of at least two hours and there is no
     opening between the store on the story next above and any
     entrance hall or other public hall or public portion of the
     dwelling.


Sec. 151. Spaces under stairs.

1.   It shall be unlawful to have a closet of any kind under any
     public stair.

2.   The space beneath every stair from the foot of the stair to
     a point where the soffit is four feet or more above the
     floor shall be entirely enclosed with unpierced fire-
     retarded partitions. Such enclosure beneath a flight of
     public stairs leading from the entrance story to the story
     next above shall be fireproof.

3.   Any unenclosed portion of the space beneath a flight of
     public stairs leading from the entrance story to the story
     next above shall be left entirely open and kept clear and
     free from encumbrance.


Sec. 152. Fire-stopping.

1.   In every wall where wooden furring is used every course of
     masonry from the under side to the top of any floor beams
     shall project a distance of at least two inches beyond each
     face of the wall that is not on the outside of the dwelling;
     and whenever floor beams run parallel to a wall and wooden
     furring is used, every such beam shall always be kept at
     least two inches away from the wall, and the space between
     the beams and the wall shall be built up solidly with
     brickwork from the under side to the top of the floor beams.

2.   Whenever a wall is studded off, the space between an inside
     face of the wall and the studding at any floor level shall
     be fire-stopped. Every space between beams directly over a
     studded-off space shall be fire-stopped by covering the
     bottom of the beams with metal lath and plaster and placing
     a loose fill of incombustible material at least four inches
     thick on the plaster between the beams, or hollow-burned
     clay tile or gypsum plaster partition blocks, at least four
     inches thick in either case and supported by cleats, shall
     be used to fill the spaces between beams.

3.   Partitions which are not parallel with the wood floor beams
     and which separate one apartment or suite from another or
     any part of an apartment or suite from a public hall or
     other part of the dwelling outside the apartment or suite
     shall be filled in solidly with incombustible material
     between the floor beams from the plate of the partition
     below to the full depth of the floor beams.

4.   If a dwelling is within ten feet of another non-fireproof
     building or of a side lot line, such dwelling shall have its
     eaves or cornices built up solidly with masonry.

5.   The wooden frames in any cornice on any row of buildings
     shall be separated between buildings by a complete fire-
     stop.

6.   Every space between stair carriages of any non-fireproof
     stair shall be fire-stopped by a header beam at top and
     bottom. Where a stair run is not all in one room or open
     space, the stair carriages shall have an intermediate
     firestop, so located as to cut off communication between
     portions of the stair in different rooms or open spaces. The
     underside and stringers of every unenclosed stair of
     combustible material shall be fire-retarded.

7.   All partitions required to be fire-retarded shall be fire-
     stopped with incombustible material at floors, ceilings and
     roofs. Fire-stopping over partitions shall extend from the
     ceiling to the underside of any roofing above. Any space
     between the top of a partition and the underside of roof
     boarding shall be completely fire-stopped.


                             TITLE 2
                           SANITATION

Sec. 160. Water-closets.

Water-closet compartments in class B non-fireproof multiple
dwellings shall comply with the applicable provisions of section
seventy-six.


=================================================================
=================================================================


External links are for convenience and informational purposes, and in some cases, might be sponsored
content. TenantNet does not necessarily endorse or approve of any content on any external site.

TenantNet Home | TenantNet Forum | New York Tenant Information
DHCR Information | DHCR Decisions | Housing Court Decisions | New York Rent Laws
Disclaimer | Privacy Policy | Contact Us

Subscribe to our Mailing List!
Your Email      Full Name